中斷連結修正關閉

Jun 24, 2024

The MX-System series | # 8: The relay modules

High power needs to be connected safely in a control cabinet. In the control cabinet-free MX-System, relay modules are used for this. Watch this video to find out more about the different relay modules that Beckhoff offers for the MX-System.

More about this video

MX-System

MX-System

Our MX-System combines all technological innovations in automation technology in an IP67-capable modular system.

MR1307-0031-2242 | 3-channel relay, replaceable fuses, 230 V AC/7 A, residual current measurement, M12

MR1307-0031-2242 | 3-channel relay, replaceable fuses, 230 V AC/7 A, residual current measurement, M12

The MRxxxx series relay modules allow the direct switching of high power levels and can also be used in a variety of ways. The MR1307-0031-2242 relay module is used to connect ohmic or inductive 1-phase AC loads. Each of the three relay outputs carries one phase together with the neutral conductor to the outside and can switch up to 7 A. The total current is limited to 15 A. Connection is via M12 connectors.

MR3107-2901-2245 | 1-channel reversing motor starter, replaceable fuses, 7 A, safe shutdown, B23

MR3107-2901-2245 | 1-channel reversing motor starter, replaceable fuses, 7 A, safe shutdown, B23

The MRxxxx series relay modules allow the direct switching of high power levels and can also be used in a variety of ways. The MR3107-2901-2245 relay module is used to connect an ohmic or inductive 3-phase AC load. The integrated reversing contactor connection allows an asynchronous motor to be operated in both directions of rotation.

MR3107-2001-2245 | 1-channel reversing motor starter, replaceable fuses, 7 A, B23

MR3107-2001-2245 | 1-channel reversing motor starter, replaceable fuses, 7 A, B23

The MRxxxx series relay modules allow the direct switching of high power levels and can also be used in a variety of ways. The MR3107-2001-2245 relay module is used to connect an ohmic or inductive 3-phase AC load. The integrated reversing contactor connection allows a 3-phase asynchronous motor to be operated in both directions of rotation.

MR3203-1901-2244 | 2-channel direct motor starter, replaceable fuses, 2.8 A, safe shutdown, B17

MR3203-1901-2244 | 2-channel direct motor starter, replaceable fuses, 2.8 A, safe shutdown, B17

The MRxxxx series relay modules allow the direct switching of high power levels and can also be used in a variety of ways. The 2-channel MR3203-1901-2244 relay module is used to connect ohmic or inductive 3-phase AC loads.

MR3203-1001-2244 | 2-channel direct motor starter, replaceable fuses, 2.8 A, B17

MR3203-1001-2244 | 2-channel direct motor starter, replaceable fuses, 2.8 A, B17

The MRxxxx series relay modules allow the direct switching of high power levels and can also be used in a variety of ways. The 2-channel MR3203-1001-2244 relay module is used to connect ohmic or inductive 3-phase AC load.

MR4307-1931-2242 | 3-channel solid-state relay, replaceable fuses, 230 V AC/7 A, residual current measurement, safe shutdown, M12, 3-channel analog input, M12

MR4307-1931-2242 | 3-channel solid-state relay, replaceable fuses, 230 V AC/7 A, residual current measurement, safe shutdown, M12, 3-channel analog input, M12

The MRxxxx series relay modules allow the direct switching of high power levels and can also be used in a variety of ways. The MR4307-1931-2242 relay module is used to connect ohmic or inductive 1-phase AC loads. Each of the three solid-state relay outputs carries one phase together with the neutral conductor to the outside and can switch up to 7 A. The total current is limited to 15 A. Connection is via M12 connectors.

MR4107-1021-2245 | 1-channel solid-state relay, replaceable fuses, 400 V AC/7 A, B23, 1-channel analog input, M12

MR4107-1021-2245 | 1-channel solid-state relay, replaceable fuses, 400 V AC/7 A, B23, 1-channel analog input, M12

The MRxxxx series relay modules allow the direct switching of high power levels and can also be used in a variety of ways. The MR4107-1021-2245 relay module is used to connect an ohmic or inductive 3-phase AC load.

MR4307-1031-2242 | 3-channel solid-state relay, replaceable fuses, 230 V AC/7 A, residual current measurement, M12, 3-channel analog input, M12

MR4307-1031-2242 | 3-channel solid-state relay, replaceable fuses, 230 V AC/7 A, residual current measurement, M12, 3-channel analog input, M12

The MRxxxx series relay modules allow the direct switching of high power levels and can also be used in a variety of ways. The MR4307-1031-2242 relay module is used to connect ohmic or inductive 1-phase AC loads. Each of the three solid-state relay outputs carries one phase together with the neutral conductor to the outside and can switch up to 7 A. The total current is limited to 15 A. Connection is via M12 connectors.

MR4107-1941-2245 | 1-channel solid-state relay, replaceable fuses, 400 V AC/7 A, residual current measurement, safe shutdown, B23, 1-channel analog input, M12

MR4107-1941-2245 | 1-channel solid-state relay, replaceable fuses, 400 V AC/7 A, residual current measurement, safe shutdown, B23, 1-channel analog input, M12

The MRxxxx series relay modules allow the direct switching of high power levels and can also be used in a variety of ways. The MR4107-1941-2245 relay module is used to connect an ohmic or inductive 3-phase AC load.

MR4107-1041-2245 | 1-channel solid-state relay, replaceable fuses, 400 V AC/7 A, residual current measurement, B23, 1-channel analog input, M12

MR4107-1041-2245 | 1-channel solid-state relay, replaceable fuses, 400 V AC/7 A, residual current measurement, B23, 1-channel analog input, M12

The MRxxxx series relay modules allow the direct switching of high power levels and can also be used in a variety of ways. The MR4107-1041-2245 relay module is used to connect an ohmic or inductive 3-phase AC load.