Tách raSửaĐóng

Văn Phòng Đại Diện tại Việt Nam

#29.05, Tòa nhà Pearl Plaza, 561A, Đường Điện Biên Phủ
Phường 25, Quận Bình Thạnh
Thành Phố Hồ Chí Minh, Việt Nam

+84 28 7300-2439
info@beckhoff.com.vn
www.beckhoff.com/vi-vn/

EPP9022-0060 | EtherCAT P Box, with voltage diagnostics

Image similar, may contain optional accessories
EPP9022-0060 | EtherCAT P Box, with voltage diagnostics

EPP9022-0060 | EtherCAT P Box, with voltage diagnostics

EtherCAT P signal input
EtherCAT P signal output
Power supply status display:
Box supply (US)
Auxiliary voltage (UP)
1 | Tx+/GNDS
2 | Rx+/GNDP
3 | Rx-/UP
4 | Tx-/US
1 | +24 V DC US
2 | +24 V DC UP
3 | GNDS
4 | GNDP
Top view 
Connector assignment 
EPP9022-0060 | EtherCAT P Box, with voltage diagnostics

EPP9022-0060 | EtherCAT P Box, with voltage diagnostics

EtherCAT P: The one cable solution – One step closer to automation without control cabinets

EtherCAT P: The one cable solution – One step closer to automation without control cabinets

The EPP9022-0060 EtherCAT P Box can be used for diagnosing and measuring the voltages US and UP and currents IS and IP, both temporarily during commissioning and permanently during operation. Even without an EtherCAT master, the voltage range is displayed on the box by LEDs (green, yellow and red). In a running EtherCAT network, the values of US, UP, IS and IP can also be read out as process data in the master. The voltage levels for the LED displays can be adjusted by CoE.

In addition the EtherCAT P Box is equipped with an M8 power socket to which an external multimeter can be connected for measuring the voltages.

The EtherCAT P Box modules are characterized by their small and space-saving form factor.

Product status:

regular delivery

Product information

Technical dataEPP9022-0060
ProtocolEtherCAT P
Bus interfaceM8 socket, P-coded, shielded
Task within EtherCAT systemdiagnostics of the US/UP voltages and IS/IP currents
Number of channelsIN: 1 x EtherCAT P, OUT: 1 x EtherCAT P
Nominal voltage24 V DC (-15%/+20%)
Total currentfeed-in max. 3 A per US and UP
Current consumption from UStyp. 100 mA
Current rating per portmax. 3 A per US and UP
Special featuresdiagnostic LED for US, diagnostic LED for UP
Weightapprox. 90 g
Operating/storage temperature-25…+60°C/-40…+85°C
Vibration/shock resistanceconforms to EN 60068-2-6/EN 60068-2-27
EMC immunity/emissionconforms to EN 61000-6-2/EN 61000-6-4
Protect. rating/installation pos.IP65/66/67 (conforms to EN 60529)/variable
Approvals/markingsCE, UL
Housing dataEPPxxxx-006x
Dimensions (W x H x D)30 mm x 86 mm x 22 mm
MaterialPA6 (polyamide)
Installation2 fixing holes 3.5 mm diameter for M3

Loading content ...

Loading content ...

Loading content ...

Loading content ...

© Beckhoff Automation 2024 - Terms of Use