OdpniPripniZapri

EP2534-0002 | EtherCAT Box, 4-channel PWM output, 24 V DC, 2 A, M12, current-controlledNew

Image similar, may contain optional accessories
EP2534-0002 | EtherCAT Box, 4-channel PWM output, 24 V DC, 2 A, M12, current-controlled

EP2534-0002 | EtherCAT Box, 4-channel PWM output, 24 V DC, 2 A, M12, current-controlled

EtherCAT signal input
EtherCAT signal output
M12 I/O connection sockets
Signal status display
Labeling areas
Power supply status display:
Box supply (US)
Auxiliary voltage (UP)
Power supply feed
Power supply downstream
connection
1 | Tx+
2 | Rx+
3 | Rx-
4 | Tx-
1 | n. c.
2 | n. c.
3 | PWM-
4 | PWM+
5 | Shield
1 | +24 V DC US
2 | +24 V DC UP
3 | GNDS
4 | GNDP
Top view 
I/O connection 
Connector assignment 
EP2534-0002 | EtherCAT Box, 4-channel PWM output, 24 V DC, 2 A, M12, current-controlled

EP2534-0002 | EtherCAT Box, 4-channel PWM output, 24 V DC, 2 A, M12, current-controlled

The EP2534-0002 EtherCAT Box regulates the output current by pulse width control of the peripheral voltage on four channels. The current values ranging from 0 to a maximum output current of 2 A are specified by the automation device through a 16-bit value. The sum current of all outputs is limited to 4 A. The output stages are protected against overload and short circuit. The signal state of the channels is indicated by LEDs. The signal connection is established via screw-type M12 connectors. One channel is available per M12 socket.

Product status:

product announcement | estimated market release 4th quarter 2024

Product information

Technical dataEP2534-0002
ProtocolEtherCAT
Bus interface2 x M8 socket, 4-pin, a-coded, shielded
Number of outputs4
Output connectionsM12 x 1, 5-pin, a-coded
Load typeinductive > 1 mH
Max. output current2 A per channel, ∑ 4 A
Short-circuit currenttyp. < 4 A
PWM clock frequency30 kHz default
Distributed clocks
Current consumption from UStyp. 130 mA
Auxiliary power currenttyp. 20 mA + load
Duty factor0…100% (current-controlled)
Resolution10 bit
Reverse voltage protectionyes
Power supply connectionfeed: 1 x M8 male socket, 4-pin, a-coded; downstream connection: 1 x M8 female socket, 4-pin, a-coded
Electrical isolation500 V
Special features1 output per M12 connector, PWM current controlled
Weightapprox. 165 g
Operating/storage temperature-25…+60°C/-40…+85°C
Vibration/shock resistanceconforms to EN 60068-2-6/EN 60068-2-27
EMC immunity/emissionconforms to EN 61000-6-2/EN 61000-6-4
Protect. rating/installation pos.IP65/66/67 (conforms to EN 60529)/variable
Approvals/markingsCE, UL
Housing data8 x M8, 4 x M12
Dimensions (W x H x D)30 mm x 126 mm x 26.5 mm
MaterialPA6 (polyamide)
Installation2 fixing holes 3.5 mm diameter for M3