SbloccaBloccaChiudi

Sede centrale Svizzera
Beckhoff Automation AG

Rheinweg 7
8200 Schaffhausen, Svizzera

+41 52 633 40 40
info@beckhoff.ch
www.beckhoff.com/it-ch/

Supporto tecnico Schaffhausen (German)

+41 52 633 40 40
support@beckhoff.ch
Modulo di contatto

Supporto tecnico Arbon (German)

+41 71 447 10 80
support@beckhoff.ch

Supporto tecnico Lyssach (German)

+41 34 447 44 88
support@beckhoff.ch

Supporto tecnico Yverdon-les-Bains (French)

+41 24 447 27 00
support@beckhoff.ch

Supporto tecnico Losone (Italian)

+41 91 792 24 40
support@beckhoff.ch

EL6184 | EtherCAT Terminal, 4-channel communication interface, HART, secondary masterNew

Image similar, may contain optional accessories
EL6184 | EtherCAT Terminal, 4-channel communication interface, HART, secondary master

EL6184 | EtherCAT Terminal, 4-channel communication interface, HART, secondary master

Run
HART/Error 1, 2
HART/Error 3, 4
Power contact
+24 V
Power contact 0 V
Input 1
GND
GND
Input 3
Input 2
GND
GND
Input 4
Top view 
Contact assembly 
Image similar, may contain optional accessories
EL6184 | EtherCAT Terminal, 4-channel communication interface, HART, secondary master

EL6184 | EtherCAT Terminal, 4-channel communication interface, HART, secondary master

EL6184 | EtherCAT Terminal, 4-channel communication interface, HART, secondary master

EL6184 | EtherCAT Terminal, 4-channel communication interface, HART, secondary master

EL6184 | EtherCAT Terminal, 4-channel communication interface, HART, secondary master

EL6184 | EtherCAT Terminal, 4-channel communication interface, HART, secondary master

EtherCAT Terminal for HART-capable field devices

EtherCAT Terminal for HART-capable field devices

The EL6184 offers four interfaces for integrating HART-capable field devices. The EtherCAT Terminal serves as a secondary master and can be seamlessly integrated into existing connections. Maintenance and diagnostic data, for example, can be retrieved from field devices, as is the case in the context of NAMUR Open Architecture (NOA).

Product status:

regular delivery

Product information

Technical dataEL6184
Number of inputs4
TechnologyHART (version 7)
Power supplyvia the E-bus
Internal resistance100.1 kΩ
Dielectric strengthmax. 30 V
Electrical isolation500 V (E-bus/signal voltage)
Current consumption power contacts
Current consumption E-bustyp. 70 mA
Weightapprox. 60 g
Operating/storage temperature-25…+60°C/-40…+85°C
Relative humidity95%, no condensation
Vibration/shock resistanceconforms to EN 60068-2-6/EN 60068-2-27
EMC immunity/emissionconforms to EN 61000-6-2/EN 61000-6-4
Protect. rating/installation pos.IP20/variable
Approvals/markingsCE, UL, Ex, IECEx (in preparation)
Housing dataEL-12-8pin
Design formcompact terminal housing with signal LEDs
Materialpolycarbonate
Dimensions (W x H x D)12 mm x 100 mm x 68 mm
Installationon 35 mm DIN rail, conforming to EN 60715 with lock
Side by side mounting by means ofdouble slot and key connection
Markinglabeling of the BZxxx series
Wiringsolid conductor (s), flexible conductor (st) and ferrule (f): spring actuation by screwdriver
Connection cross-sections*: 0.08…2.5 mm²,
st*: 0.08…2.5 mm²,
f*: 0.14…1.5 mm²
Connection cross-section AWGs*: AWG28…14,
st*: AWG28…14,
f*: AWG26…16
Stripping length8…9 mm
Current load power contactsImax: 10 A

*s: solid wire; st: stranded wire; f: with ferrule